Wind Uplift Tested Roof Assemblies
Information at your finger tipsAdhesive Applied Roofing System (AARS)
SBS System #1 - IKO
Wind Pressure: 100 psf / 150 psf
System Components:
Steel deck
IKO Modified Vapour Protector (MVP) Vapour Retarder
Plasti-Fab 51mm min. Expanded Polystyrene (EPS) Insulation - adhered
51mm IKOTherm Polyisocyanurate Insulation - adhered
IKO Protectobase 180 - Adhered in IKO Millenium Adhesive (305mm oc)
IKO Torchflex TP-180 Cap
SBS System #2 - Soprema
Wind Pressure: 50 psf / 75 psf
System Components:
22 ga. Steel deck
Sopravap’r Vapour Retarder
51mm min. Plastispan Type 2 Insulation - Adhered
51mm Sopra-ISO Polyisocyanurate Insulation - Adhered
Sopralene Flam 180 - Adhered
Attachment using Soprema Duotack Adhesive @ 305 mm O.C.
Sopralene Flam 250-GR Cap Sheet
Mechanically Attached Roofing System (MARS)
SBS System #1 - IKO
Wind Pressure:70 psf / 105 psf
System Components:
22 ga. Steel deck
IKO Modified Vapour Protector (MVP) Sand Vapour Retarder
51mm min. Plastispan Type 2 Insulation
51mm IKOTherm Polyisocyanurate Insulation
IKO Protectobase 180
Mechanically attached using 22” O.C. fastener spacing and 16” O.C. row spacing
IKO Torchflex TP – 180 Cap Sheet
SBS System #2
Wind Pressure: 100 psf / 150 psf
System Components:
22 ga. Steel deck
IKO Modified Vapour Protector (MVP) Sand Vapour Retarder
51mm min. Plastispan Type 2 Insulation
51mm IKOTherm Polyisocyanurate Insulation
IKO Protectobase 180
Mechanically attached using 14” O.C. fastener spacing and 12” O.C. row spacing
IKO Torchflex TP – 180 Cap Sheet
TPO System #1 - Carlisle
Wind Pressure: 62.3 psf / 93.5 psf
System Components:
22 ga. Steel deck
Vapair Seal MD Vapour Retarder
51mm min. Plastispan Type 2 Insulation
51mm Insulbase HD Polyisocyanurate Insulation
1/4” thk. DensDeck Prime coverboard
Mechanically attached using XHP fasteners and Rhinobond Plates
Sure-Weld TPO Membrane (Attached using Induction welding)
TPO System #2 - Firestone Elevate
Wind Pressure: 75 psf / 112.5 psf
System Components:
22 ga. Steel deck
Elevate V-force Vapour Retarder
51mm min. Plastispan Type 2 Insulation
51mm Elevate Resista Polyisocyanurate Insulation
Mechanically attached using Firestone HD fasteners and Invisiweld Plates
Firestone Ultraply 60 mil TPO Membrane (Attached using Induction welding)
TPO System #3 - Firestone Elevate
Wind Pressure: 87.5 psf / 131.25 psf
System Components:
22 ga. Steel deck
Elevate V-force Vapour Retarder
51mm min. Plastispan Type 2 Insulation
38mm min. Plastispan Type 2 Insulation
1/2” thk. Isogard HD coverboard
Mechanically attached using Firestone HD fasteners and Invisiweld Plates
Firestone Ultraply 60 mil TPO Membrane (Attached using Induction welding)
Partially Attached Roofing System (PARS)
TPO System #1 - Firestone Elevate
Wind Pressure: 50 psf / 75 psf
System Components:
22 ga. Steel deck
Elevate V-force Vapour Retarder
51mm min. Plastispan Type 2 Insulation
51mm Elevate Resista Polyisocyanurate Insulation
Mechanically attached using Firestone HD fasteners and Plates
Firestone Ultraply 60 mil TPO Membrane (Attached using Bonding Adhesive)