Adhesive Applied Roofing System (AARS)

SBS System #1
(Using IKO Roofing Membrane)


Wind Pressure: 100 psf / 150 psf


System Components:

Steel deck

IKO Modified Vapour Protector (MVP) Vapour Retarder

Plasti-Fab 51mm min. Expanded Polystyrene (EPS) Insulation - adhered

51mm IKOTherm Polyisocyanurate Insulation - adhered

IKO Protectobase 180 - Adhered in IKO Millenium Adhesive (305mm oc)

IKO Torchflex TP-180 Cap


SBS System #2
(Using Soprema Roofing Membrane)


Wind Pressure: 50 psf / 75 psf


System Components:

22 ga. Steel deck

Sopravap’r Vapour Retarder

51mm min. Plastispan Type 2 Insulation - Adhered

51mm Sopra-ISO Polyisocyanurate Insulation - Adhered

Sopralene Flam 180 - Adhered

Attachment using Soprema Duotack Adhesive @ 305 mm O.C.

Sopralene Flam 250-GR Cap Sheet




Mechanically Attached Roofing System (MARS)

SBS System #1
(Using IKO Roofing Membrane)


Wind Pressure: 70 psf / 105 psf


System Components:

22 ga. Steel deck

IKO Modified Vapour Protector (MVP) Sand Vapour Retarder

51mm min. Plastispan Type 2 Insulation

51mm IKOTherm Polyisocyanurate Insulation

IKO Protectobase 180

Mechanically attached using 22” O.C. fastener spacing and 16” O.C. row spacing

IKO Torchflex TP – 180 Cap Sheet


SBS System #2
(Using IKO Roofing Membrane)


Wind Pressure: 100 psf / 150 psf


System Components:

22 ga. Steel deck

IKO Modified Vapour Protector (MVP) Sand Vapour Retarder

51mm min. Plastispan Type 2 Insulation

51mm IKOTherm Polyisocyanurate Insulation

IKO Protectobase 180

Mechanically attached using 14” O.C. fastener spacing and 12” O.C. row spacing

IKO Torchflex TP – 180 Cap Sheet


TPO System #1
(Using Carlisle Roofing Membrane)


Wind Pressure: 62.3 psf / 93.5 psf


System Components:

22 ga. Steel deck

Vapair Seal MD Vapour Retarder

51mm min. Plastispan Type 2 Insulation

51mm Insulbase HD Polyisocyanurate Insulation

1/4” thk. DensDeck Prime coverboard

Mechanically attached using XHP fasteners and Rhinobond Plates

Sure-Weld TPO Membrane (Attached using Induction welding)


TPO System #2
(Using Firestone Elevate Roofing Membrane)


Wind Pressure: 75 psf / 112.5 psf


System Components:

22 ga. Steel deck

Elevate V-force Vapour Retarder

51mm min. Plastispan Type 2 Insulation

51mm Elevate Resista Polyisocyanurate Insulation

Mechanically attached using Firestone HD fasteners and Invisiweld Plates

Firestone Ultraply 60 mil TPO Membrane (Attached using Induction welding)


TPO System #3
(Using Firestone Elevate Roofing Membrane)


Wind Pressure: 87.5 psf / 131.25 psf


System Components:

22 ga. Steel deck

Elevate V-force Vapour Retarder

51mm min. Plastispan Type 2 Insulation

38mm min. Plastispan Type 2 Insulation

1/2” thk. Isogard HD coverboard

Mechanically attached using Firestone HD fasteners and Invisiweld Plates

Firestone Ultraply 60 mil TPO Membrane (Attached using Induction welding)




Partially Attached Roofing System (PARS)

TPO System #1
(Using Firestone Elevate Roofing Membrane)


Wind Pressure: 50 psf / 75 psf


System Components:

22 ga. Steel deck

Elevate V-force Vapour Retarder

51mm min. Plastispan Type 2 Insulation

51mm Elevate Resista Polyisocyanurate Insulation

Mechanically attached using Firestone HD fasteners and Plates

Firestone Ultraply 60 mil TPO Membrane (Attached using Bonding Adhesive)